Safety & Degraded Modes

Current working version

This page is the current working version of the safety documentation. It is clearly not the final version yet: the project is still under development, and safety analysis and implementation will continue to evolve as the robot is built and tested.

Safety is the most important part of this project. However, I am currently the only person working on it, and the robot itself is still being developed. A robot that does not exist cannot be tested or made safer. For that reason, development is continuing in parallel with the safety work. The goal is to keep safety visible and to implement the necessary protections progressively, before any real-world operation.

The table below records the current documented and implemented failure responses. It is an engineering snapshot, not a claim that all safety issues have been solved. Missing, uncertain, or not-yet-implemented behavior must be resolved before the robot is considered ready for operation.

Current FMEA

Every row in this table is directly sourced from documented, implemented behavior.

Failure Detected by Delay Reaction Visible effect Recovery
Controller link lost while the robot is walking or running Pi (source staleness) 500 ms Auto-decelerate to STANDING Robot stops itself Automatic once the link returns
Controller link lost in any state Pi (source staleness) 10 s Auto-transition to SITTING; latch control mode to plain RC Robot sits; background behaviors are disabled Link return does not clear the latch; explicit source action is required
Tilt exits the safety zone Pico tilt monitor Immediate Cut motor power Motors stop immediately The subsequent FALLING protection remains available
Tilt out of range Pico tilt monitor ~5 s sustained Auto-transition to FALLING; legs fold; optional alert sound Robot lowers itself defensively Automatic once tilt is back in range, then SITTING
Pi to XIAO (head) link lost XIAO watchdog 200 ms Failsafe: servo torque cut and vibrator off Head goes limp Automatic on the next valid command
Emergency stop from any source Arbiter (OR across sources) Immediate Robot returns to SAFE Motors are de-powered Clears instantly when no source signals that it is active
Pack voltage low (9.6 V) Nano Every (INA226) On threshold crossing Clean shutdown sequence: notify, halt, then cutoff Robot sits, then powers off Manual: recharge and power cycle
Cell undervoltage (2.8 V) BMS hardware Threshold-based Hard circuit cutoff Total power loss Manual: recharge
Overcurrent (60 A) or short circuit BMS hardware 1 s for overcurrent; 300 µs for short circuit Hard circuit cutoff Total power loss Manual: recharge
Servo overload, overvoltage, or overheat Servo firmware 2 s for overload; immediate for voltage and temperature Torque cut on that servo Affected joint goes limp Auto-rearm on a new setpoint or after returning to a safe range